Where this text comes from
- Citation
- 40 CFR Part 60, Subpart OOO
- Official title
- Subpart OOO—Standards of Performance for Nonmetallic Mineral Processing Plants
- Text as of
- eCFR current through 2026-10-28, retrieved 2026-10-30
- Latest amendment
- 2016-12-23
- Source note
- 74 FR 19309, Apr. 28, 2009, unless otherwise noted.
Headings and quoted sections on this page are copied from the eCFR text of Subpart OOO without changes. AirPermitHub checks eCFR every week and reviews any change before publishing it, so this page can trail eCFR by a few days. eCFR is maintained by the Office of the Federal Register and the Government Publishing Office. It is not an official legal edition of the CFR, and it does not show how an agency has applied the rule in a permit.
Where to look in Subpart OOO
Sections sorted by the words in their eCFR headings. Read the full section before relying on it; requirements often sit in more than one place.
Who the subpart covers, in the rule's own words
The sections that set out what the subpart applies to, quoted in full from eCFR. Dates, sizes, and other figures are the rule's, not AirPermitHub's.
§ 60.670 Applicability and designation of affected facility.
Open in eCFR(a)(1) Except as provided in paragraphs (a)(2), (b), (c), and (d) of this section, the provisions of this subpart are applicable to the following affected facilities in fixed or portable nonmetallic mineral processing plants: each crusher, grinding mill, screening operation, bucket elevator, belt conveyor, bagging operation, storage bin, enclosed truck or railcar loading station. Also, crushers and grinding mills at hot mix asphalt facilities that reduce the size of nonmetallic minerals embedded in recycled asphalt pavement and subsequent affected facilities up to, but not including, the first storage silo or bin are subject to the provisions of this subpart.
(2) The provisions of this subpart do not apply to the following operations: All facilities located in underground mines; plants without crushers or grinding mills above ground; and wet material processing operations (as defined in § 60.671).
(b) An affected facility that is subject to the provisions of subparts F or I of this part or that follows in the plant process any facility subject to the provisions of subparts F or I of this part is not subject to the provisions of this subpart.
(c) Facilities at the following plants are not subject to the provisions of this subpart:
(1) Fixed sand and gravel plants and crushed stone plants with capacities, as defined in § 60.671, of 23 megagrams per hour (25 tons per hour) or less;
(2) Portable sand and gravel plants and crushed stone plants with capacities, as defined in § 60.671, of 136 megagrams per hour (150 tons per hour) or less; and
(3) Common clay plants and pumice plants with capacities, as defined in § 60.671, of 9 megagrams per hour (10 tons per hour) or less.
(d)(1) When an existing facility is replaced by a piece of equipment of equal or smaller size, as defined in § 60.671, having the same function as the existing facility, and there is no increase in the amount of emissions, the new facility is exempt from the provisions of §§ 60.672, 60.674, and 60.675 except as provided for in paragraph (d)(3) of this section.
Show the rest of § 60.670 (4 more paragraphs)Hide the rest of § 60.670
(2) An owner or operator complying with paragraph (d)(1) of this section shall submit the information required in § 60.676(a).
(3) An owner or operator replacing all existing facilities in a production line with new facilities does not qualify for the exemption described in paragraph (d)(1) of this section and must comply with the provisions of §§ 60.672, 60.674 and 60.675.
(e) An affected facility under paragraph (a) of this section that commences construction, modification, or reconstruction after August 31, 1983, is subject to the requirements of this part.
(f) Table 1 of this subpart specifies the provisions of subpart A of this part 60 that do not apply to owners and operators of affected facilities subject to this subpart or that apply with certain exceptions.
Every section in Subpart OOO
7 sections and 3 tables, in eCFR order. Each link opens the official text.
- § 60.670Applicability and designation of affected facility.Amended 2016-12-23
- § 60.671Definitions.Amended 2016-12-23
- § 60.672Standard for particulate matter (PM).Amended 2016-12-23
- § 60.673Reconstruction.Amended 2016-12-23
- § 60.674Monitoring of operations.Amended 2016-12-23
- § 60.675Test methods and procedures.Amended 2016-12-23
- § 60.676Reporting and recordkeeping.Amended 2016-12-23
Tables and appendices
Amendment history
Dates on which eCFR records a change to any section of Subpart OOO, newest first.
- 2016-12-23
To read the rulemakings behind these dates, search the Federal Register for Subpart OOO. New EPA air rules and proposals also appear in the Federal Air Rule Tracker.
AirPermitHub provides educational, engineering, research, and compliance-support information. Information provided by the platform does not constitute legal advice and should not replace review of applicable regulations, permits, agency guidance, or consultation with qualified professionals. Full disclaimer